    在测试进行中,在流量从最小流量到最大流量下,泵的速度需要从最小速到设计全速之间,应至少存在8个或以上等距离流量增流点,(包括最小流量和设计流量)用以呈现性能、功率和效率曲线图。测试用水的水温应为设计水温。在泵工作范围内,每台泵的实际汽蚀余量的要求需在测试中确定
    During testing the pumps shall be run from minimum to full design speed over the full capacity range from minimum flow to maximum flow at a minimum of 8 or more equally spaced flow increment points including minimum flow and design flow to establish the pump characteristic, power, and efficiency curves. The tests shall be performed using water at the design temperature. The actual NPSH requirements of each pump over the pump operating range shall be determined during pump tests.